Fire resistant cables with CPR – Dca for Offshore Installations, Campus Backbone, Campus Distribution cabling, General purpose indoor/outdoor LAN,
Outdoor Plant Duct Installation
General Construction: The cable contains SM G652D TIA/EIA 598-C color coded optical fibers, each with a 250µm outer diameter. The optical fibers are contained in a loose tube filled with a thixotropic gel. The tube is wrapped with a mica tape for heat protection, reinforced and protected by waterblocking fiberglass strength yarns and jacketed.
Outer Jacket Material: FR-LSZH
Outer Diameter: 11,7 mm nom.
Weight: 147 kg/km
Buffer Material: HFFR
Tube Diameter: 2,5 mm nom.
Central Strength Member: FRT
Number of fibers: 48
Number of Tubes: 4
Waterblocking: Dry Waterblocking
Rip-Cords: Yes 2pcs
Outer Jacket Color: Black
Applicable Standards: IEC 60794-1-21/22, IEC 60794
Flammability Rating: IEC 60331, IEC 60331-25, IEC 60331 FE 90, IEC 60332-3 , IEC 60754-1, IEC 60754-2, IEC 61034-1/2, EN 50575:2014 Dcas2d2a3 (CPR)
Installation: Guidelines as per IEC TR 62691