Raritan PDU-1P 32A 20+4 C13/C19-3m Basic PDU

Raritan PDU-1P 32A 20+4 C13/C19-3m

Basic PDU

Artikelnummer: NX1-B1300
BeskrivningDokumentation
Beskrivning
Basic 0U PDU, 1 Phase, 32A, 20C13 + 4C19 locking outlets, 3 meters cord and IEC 60309 plug

1. KEY FEATURES

NX1 PDUs provide electric power for IT equipment in 19” enclosures.

They have been designed with specific features for Data Center applications.

Each C13 and C19 outlets are numbered and equipped with a cord locking (100 Newton retention force).
The circuits of the 32A PDUs are equipped with hydraulic magnetic circuit protection. Hydraulic magnetic circuit breakers are not affected by ambient temperature.
High ambient temperature rating: 60°C
Easy installation thanks to 330° rotating cable input and button-type brackets

2. INPUT
Input Plug: IEC 60309 32A 2P+E
Cord Length: 3m - 9.84 ft
Cord Entry: Rotating (330°), bottom front
Cable Type: HO7RNF 3G6
Maximum Input Current: 32A
Nominal Input Voltage: 230V, Single-phase
Rated Input Voltage: 200 - 240V
Input Frequency: 50/60Hz
Power Capacity: 7.4kW at 230V

3. OUTPUT
Nominal Output Voltage: 230V
Outlet type: 20 C13 + 4 C19
Cord locking system: Yes
Cord Retention: 100 N
Circuit breakers: Yes
Circuit breakers type: Magnetic Hydraulic (curve D)

Cable locking system on C13/C19 sockets:
The cable is locked mechanically into the socket to prevent any unintended disconnection (caused by maintenance, vibrations, etc.).
Pull-out force 100 N
This universal solution is compatible with any standard compliant cord type on the market

Magnetic hydraulic MCB:
Benefits of magnetic hydraulic technology :
As opposed to magnetic-thermal that needs to be de-rated, this technology is not affected by ambient temperature increase.
The tripping of an MCB with this technology is always accurate at the rated current.

Rated current : 16A
Rated voltage : 250 V
Frequency : 50/60 Hz
Number of poles : 1 pole as standard (cat. ref.) , 2 poles as CTO option
Breaking capacity (Icn) : 3000

Approvals : UL/CSA, VDE, CCC

4. MECHANICAL FEATURES
- Casings: 6060 T5-R19 natural anodised aluminium
- Outlet modules:
PC/ABS
CW507L (CuZn 36) brass
- Fixing brackets:
DC01-A-m galvanised steel

Color: Aluminium grey (casing) / black (outlet modules)
Casing: Zero-U, aluminium
IP: 20
IK: 04

5. ENVIRONMENTAL CHARACTERISTICS
Storage and transport temperature: -20 to +70°C
Operating temperature: +5°C to +60°C
Operating Relative Humidity: 5% to 95%
Operating Elevation: 0 - 2000 m

6. MOUNTING SOLUTIONS
6.1 INCLUDED
Delivered with 2 different sets for mounting in a rack.

Set of 2 buttons
Screwless fixing. The height of the fixing centre can be set at any point along the full height of the PDU by sliding the button slots into the groove on the rear of the PDU. Tightened using a screwdriver.

Set of 2 standard fixing brackets
Screw-fixing (screws not included)
Fixing centres (min.-max.) with standard brackets : 1104mm -1124mm

6.2 OPTION
Brackets for Nexpand racks
Screw-fixing (2 screws included)
Ref. 981227 Set of 2 brackets (for 1 PDU)
Ref. 981228 Set of 20 brackets (for 10 PDUs

7. STANDARDS AND REGULATION
7.1 STANDARDS
Application - Standards
Safety - IEC 62368-1
C13 and C19 connectors for electrical equipment - IEC 60320-2-2, IEC 62368-1
Circuit breakers - IEC 60934
Industrial plugs - IEC 60309-1
Information and communication technology equipment - IEC 62368-1
Electromagnetic compatibility - EN 62311 (2008) EMF, EN 50491-5-2, EN 50491-5-3, EN 55035, EN 55032, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-3-2

7.2 REGULATORY APPROVALS
CE, UKCA, CMIM
RoHS directive (Restriction of Hazardous Substances).
REACH regulations (Registration, Evaluation, Authorisation & restriction of CHemicals).


GENERAL INFORMATION NX1

OUTLET TYPES
• Our standard offer delivers a combination of C13 and C19
• PDUs can be configured by combining up to 3 outlet types: C13, C19, German, UTE or BS 1363

NUMBERING AND COLOR-CODING PER CIRCUIT OR PER FULL UNIT
• Our offer delivers black PDUs with numbering starting close to the inlet
• PDUs can be configured with numbering starting or finishing close to the inlet
• Various finishes available: red, blue, green, magenta, grey, orange, yellow, white or brown

FORM FACTOR 0U, 1U
• PDUs can be configured for 19’’ mounting or vertical mounting
• The new chassis design allows for high density C13 and C19 outlets to pack the most outlets in the smallest form factor

INPUT TYPE AND CORD LENGTH
• Choose inlet position:
- top or bottom for 0U PDUs
- left or right for 1U PDUs
• Choose inlet cord type:
- at the front with rotatable cable entry
- at the end with cable gland
- IEC 60306, C20, C14, German, French, British or stripped connector
• Choose cable length from 0.5 to 6 meters in steps of 0.5 and between standard cables or LSZH ones
• Choose PDUs without inlet cords but inlet connections instead. C20 inlet, C14 inlet or to be wired on terminal block

ADDITIONAL FUNCTIONS
• LED power indicator available as an option to visually identify a powered PDU